

The high‑capacity WG9112530355 Steyr King Expansion Tank is engineered to maintain optimal coolant levels and pressure in SINOTRUK Howo heavy trucks, preventing overheating and cavitation. When you select genuine Howo Truck Parts, you guarantee perfect fitment, leak‑free operation, and extended engine life. This expansion tank is molded from high‑temperature engineering plastic with a reinforced neck and a transparent coolant level strip. Designed for Steyr King engines, it withstands pressures up to 1.5 bar and temperatures of 120°C, ensuring your HOWO truck’s cooling system remains reliable under extreme loads.
The WG9112530355 expansion tank is manufactured from high‑density polypropylene (PP) reinforced with 30% glass fiber, offering exceptional resistance to coolant chemicals and thermal cycling. Its semi‑transparent body allows quick visual inspection of coolant level, while the molded MAX/MIN marks eliminate guesswork. For SINOTRUK Howo trucks fitted with Steyr King engines (e.g., WD615, WD618 series), this expansion tank is a direct OEM replacement. The tank features three integrated ports: a main coolant return from the radiator, a bleed line from the engine head, and an overflow connection to the recovery bottle.
Field data from over 500 HOWO trucks operating in long‑haul and mining shows that the WG9112530355 reduces coolant loss by 90% and eliminates cap sealing failures common with aftermarket tanks. The tank’s reinforced filler neck accepts the original pressure cap (1.5 bar) and features a double‑seal design that prevents steam escape. Additionally, the integral baffle inside the tank separates air bubbles from returning coolant, preventing pump cavitation. Many fleets report a 50% reduction in cooling system maintenance costs after switching to this genuine tank.
| Parameter | Specification |
|---|---|
| OEM Number | WG9112530355 |
| Product Name | Steyr King Expansion Tank |
| Application | SINOTRUK HOWO with Steyr King engines (WD615/WD618) |
| Material | PP+30% glass fiber, UV‑stabilized |
| Total Capacity | 8.5 liters (2.25 gallons) |
| Working Pressure | 1.5 bar (22 psi) max |
| Temperature Range | -40°C to +120°C |
| Filler Neck Type | Bayonet, 43 mm diameter |
| Port Configuration | 3 ports (32 mm, 25 mm, 16 mm ID) |
| Weight | 1.2 kg |
The WG9112530355 expansion tank is 100% pressure‑tested at 2.0 bar to ensure leak‑proof integrity. Each tank is inspected for flash and sink marks, and the mounting brackets are checked for correct alignment. The molded‑in hose barbs are designed with retaining ribs to prevent hose slippage even under high vibration. For SINOTRUK HOWO fleets, this tank eliminates the common issues of brittle cracking and cap misalignment, keeping the cooling system pressurized and free of air locks.
The engineering behind the WG9112530355 focuses on thermal stability, chemical resistance, and structural integrity. The glass‑reinforced polypropylene compound has a heat deflection temperature of 135°C, far exceeding standard tanks. Independent lab tests show that this tank withstands 5,000 hours of thermal cycling from -40°C to +110°C without developing cracks – 4x longer than aftermarket tanks. The internal baffle design reduces coolant turbulence, allowing trapped air to escape through the bleed port, which prevents localized overheating.
Installation of the WG9112530355 expansion tank is straightforward: remove the old tank, clean the mounting bracket, and transfer the pressure cap. The tank’s three ports align exactly with the original hoses, requiring no cutting or adapters. Many workshops report a 55% reduction in replacement time thanks to the tank’s pre‑installed grommets and captive mounting nuts. For maximum safety, always use a new pressure cap and torque the mounting bolts to 12 Nm. Periodically inspect the tank for discoloration or swelling, which may indicate coolant contamination.
PP+30% glass fiber withstands 120°C continuous operation – no warping or cracking.
Semi‑transparent body with MAX/MIN marks – instant visual check without opening the cap.
Internal baffle removes air bubbles from returning coolant – prevents pump cavitation.
Real‑world data: 600,000 km lifespan – 3x longer than aftermarket tanks, no brittle failure.
Proper maintenance of the WG9112530355 expansion tank includes inspecting the cap seal and the tank body for cracks every 50,000 km. The tank should be flushed with clean water when changing coolant to remove sediment. For SINOTRUK HOWO trucks operating in extremely cold climates, ensure the coolant mixture has sufficient antifreeze concentration to prevent freezing inside the tank. Always use a genuine pressure cap with the correct rating (1.5 bar) to avoid over‑pressurizing the tank.
Compared to aftermarket expansion tanks, the WG9112530355 exhibits superior dimensional stability and chemical resistance. Aftermarket tanks often warp around the mounting holes, causing coolant leaks, and their plastic degrades quickly when exposed to diesel fumes. This genuine tank is formulated to resist glycol, diesel, and oil contamination, maintaining its mechanical properties for years. For fleet managers, using this genuine tank reduces coolant loss and overheating‑related engine downtime by 85%, saving approximately $1,500 per truck annually.
The WG9112530355 expansion tank is also compatible with SINOTRUK HOWO models including the ZZ4257, A7, T7H, and new HOWO MAX with Steyr King engines. It directly replaces the original tank without modification. The tank’s three ports accept standard 32 mm, 25 mm, and 16 mm hoses, and the mounting brackets align with the original welded studs. Many major fleets have standardized on this tank for all their HOWO trucks, citing a 95% reduction in cooling system leak complaints and extended water pump life.
Environmental responsibility: the WG9112530355 is manufactured using 100% recyclable polypropylene and complies with REACH and RoHS standards. The molding process uses closed‑loop water cooling, reducing water consumption by 70%. By choosing this genuine part, you support sustainable manufacturing while ensuring engine protection. The tank is 100% recyclable through plastic reclamation programs.
In summary, the WG9112530355 Steyr King Expansion Tank is a vital component for any SINOTRUK HOWO heavy truck requiring reliable coolant management. Its reinforced construction, integrated level strip, and air separation baffle make it the definitive choice for fleet owners who refuse to compromise on engine protection. Whether you are hauling across deserts or through mountain passes, this tank maintains proper coolant levels and prevents overheating. Invest in the genuine article – the expansion tank trusted by SINOTRUK HOWO engineers worldwide.
Don’t let a cracked or leaking expansion tank cause an expensive engine overheat. Trust the genuine WG9112530355 – engineered to keep your HOWO truck’s cooling system trouble‑free, mile after mile. Your fleet and drivers deserve nothing less.